ACT OF JSC UKRELEKTROMASH DATED 18.01.2001
Compressor 2VM 4-24/9 M-1: output rose and holds up under load
2VM 4-24/9 M-1compressor No. 8 of the boiler and compressor section · 3 m³ receiver, working pressure 8 atm
signed by both partiesseal and the technical director's «Approved» endorsement
Key result
| EQUIPMENT | OPERATING CONDITIONS | WHAT WAS MEASURED |
|---|---|---|
| Piston compressor 2VM 4-24/9 M-1, No. 8 | Boiler and compressor section of the plant, 3 m³ receiver, working pressure 8 atm | Time to build working pressure from 0 to 8 atm |
Measurements before and after the restorative repair
| PARAMETER | BEFORE REPAIR, 08.12.2000 | AFTER, 400 h OF OPERATION |
|---|---|---|
| Time to build working pressure from 0 to 8 atm | 1 min 36 s | 1 min 00 s |
| Compressor output by filling of the 3 m³ receiver | 100 % | 160 % |
Output was determined from the time to fill the 3 m³ receiver to 8 atm; the standard instruments and sensors of the compressor unit were used for the measurements.
Conclusion of the plant commission
The results relate to the piston compressor 2VM 4-24/9 M-1 of the boiler and compressor section of JSC Ukrelektromash and to the duty of filling a 3 m³ receiver to 8 atm; on other equipment and in other duties the figures may differ. The original act with signatures and seal is published in full and available for download.
Current equivalent
Revitalizant gel for compressors and bearings →
Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.
How such units are treated: