EK-4B compressor, metro cars — Kharkiv Metro State Enterprise

← Full catalogue

IN-SERVICE CASE STUDY|URBAN ELECTRIC TRANSPORT|METRO CAR · COMPRESSOR

COMMISSION REPORT OF KHARKIV METRO STATE ENTERPRISE

EK-4B metro car compressor: faster air system charging no teardown, in service

Kharkiv Metro State Enterprise, Saltovskoye electric depot  ·  commission chaired by the chief engineer — first deputy head of the metro O. F. Demchenko, six signatories

Kharkiv, Ukraine  ·  report of 15.09.1999 · measurements 15.04–09.09.1999

PRODUCTXADO RVSrepair-and-restoration compound; the report’s conclusions say “XADO technology”
TREATED UNITEK-4B compressorcars No. 9300, 9730, 9726 · Saltovskoye electric depot
DOCUMENT TYPECompany commission report
signed and stamped

Key result

5-34%
output when charging to 6 kgf/cm², 3:33-4:16 → 3:11-3:38 min:s
3-5%
output when charging to 8 kgf/cm², 5:12-5:37 → 5:03-5:21 min:s
CARMILEAGE OVER THE OBSERVATION PERIODPERIOD AND FREQUENCY OF MEASUREMENTS
No. 930043 739 km15.04 – 03.09.1999, four measurement series
No. 973038 747 km15.04 – 03.09.1999, four measurement series
No. 972627 789 km25.05 – 09.09.1999, three measurement series

Air system charging time — first and last measurement of the period

CARPRESSUREFIRST MEASUREMENTLAST MEASUREMENTFASTER BY
No. 93006 kgf/cm²3:573:3819 s
No. 93008 kgf/cm²5:375:2116 s
No. 97306 kgf/cm²4:163:111 min 05 s
No. 97266 kgf/cm²3:333:2310 s
No. 97268 kgf/cm²5:125:039 s

Output was checked in accordance with instruction TsMetro/4135; in every subsequent series the charging time was shorter than in the previous one.

Commission conclusions

The commission of Kharkiv Metro State Enterprise recorded: “The measurement results show a trend toward a shorter time to reach pressure from 0 to 8 kgf/cm² by 16-55 s, which indicates improved compressor output owing to reduced clearances in the piston group.” For the other treated assemblies — door suspension, wheelset gearboxes, traction motor bearings — the commission stated that assessing the nature of change in the parts without teardown and part-by-part measurement is practically impossible, and noted: “there has been no negative result to date.” The commission decided to “continue the work on monitoring the friction assemblies treated with XADO technology.” The compressors were not removed from the cars: the improvement was obtained on line machines that ran from 27 789 to 43 739 km over the observation period.

The results relate to EK-4B compressors of metro cars under the service conditions of the Saltovskoye electric depot; on other equipment the figures may differ. RVS is an obsolete XADO designation, the zero-generation compounds; the current product generation is revitalizants. The original report of 15.09.1999 with signatures and stamp is published in full and available for download.

Current equivalent

Revitalizant gel for compressors and bearings →

Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.

How such units are treated: Compressor