REPORT UNDER CONTRACT No. 87/2000-PD · DIKANEVSKY TREATMENT COMPLEX
NG-750-23 air blower: metal back on the gear teeth, less energy consumed
unit No. 3STD-1250 electric motor · R-1000/1.43 gearbox · blower bearing assemblies
of friction unitsapproved by the plant's chief engineer, stamped
Key results
| UNIT | CONDITION BEFORE TREATMENT | WHAT WAS MEASURED |
|---|---|---|
| R-1000/1.43 gearbox, gear wheel — pinion pair | Tooth wear 15-25 %; 15-20 % of the active profile with pitting and deep scoring near the pitch point | Tooth thickness at four points on the wheel and on the pinion, active profile, noise |
| Blower bearing assemblies | Scraping marks and lapping patches on the shaft — bearing shell contact | Axial displacement of the rotor, main oil pump pressure |
| Unit No. 3 as a whole | Actual running time 6100 h per year | Electricity consumed, read from the plant's standard meter |
R-1000/1.43 gearbox — tooth geometry and condition after 400 hours of operation
| PARAMETER | MEASURED RESULT |
|---|---|
| Wheel — tooth thickness gain | 0.16-0.32 mm in the meshing field zone |
| Pinion — tooth thickness gain | 0.13-0.47 mm in the meshing field zone |
| Active tooth profile | 72 % → 78 % of tooth height |
| Working surface of the teeth | Appearance of a smooth ground surface: pitting and scoring — stress concentrators — have disappeared |
| Gearbox noise in operation | 5 dB below the initial level |
Tooth thickness — ShchZN-18 gear tooth vernier caliper, TU 2-034-773-89: four control points on the wheel and four on the pinion, before treatment and after 400 hours of operation.
Blower bearing assemblies and lubrication system
| PARAMETER | MEASURED RESULT |
|---|---|
| Axial displacement of the rotor | 0.25 mm → 0.21 mm |
| Main oil pump pressure | increased by 5 % |
| Bearing shell surface | Greyish colour — the metal-ceramic layer starting to form |
Measurements and inspection of the bearing shells were performed during the control inspection of the bearing assemblies after 400 hours of operation.
Electricity use by unit No. 3 — 216 hours of operation before and after treatment
| PERIOD | ELECTRICITY CONSUMED |
|---|---|
| 05.07 – 14.07.2000, before treatment, 216 h | 217 560 kWh |
| 14.08 – 23.08.2000, after treatment, 216 h | 199 680 kWh |
| Difference over an identical period | 17 880 kWh — 8.2 % |
| Per year at the actual running time of 6100 h — as calculated in the report | 504 944 kWh |
Readings of the unit's standard electricity meter were taken twice a day; the tables are signed by the plant's chief mechanical engineer and chief power engineer.
Conclusions of the plant commission
The results relate to the NG-750-23 air blower with an R-1000/1.43 gearbox and an STD-1250 electric motor on unit No. 3 of the Dikanevsky treatment complex; with other machines and operating modes the figures may differ. The restorative repair was performed by XADO LLC specialists together with the plant's personnel; the measurements were taken and signed by the services of the Dikanevsky treatment complex. The original report with signatures and stamp is published in full and available for download.
Current equivalent