TECHNICAL REPORT DATED 13.04.2001
Conveyor gearbox: the drive now draws less power with no teardown or shutdown
JSC Gomelsteklo
Key result
| EQUIPMENT | CONDITION AND DUTY | WHAT WAS MEASURED |
|---|---|---|
| Main drive gearbox of the TsPS shop conveyor | In service; drive current 50-55 A, traces of corrosion on the metal | Current drawn by the electric drive |
| Gear wheel — pinion pairs of the gearbox | 312 h of running after treatment, then teardown and inspection | Condition of the tooth working surfaces |
What was recorded after the treatment
| PARAMETER | RESULT |
|---|---|
| Current drawn by the electric drive | 50-55 A → 40 A at constant resisting torque on the input shaft and unchanged motor voltage and speed |
| Tooth working surfaces | The surface of the gear wheel — pinion pairs took on the look of a smooth ground finish |
| Coating in the tooth contact zone | An attempt to remove the coating that had formed with a fine-cut file brought no result |
| Gearbox running noise | Dropped considerably |
| Corrosion of the metal | Traces of corrosion disappeared |
The teeth were inspected after teardown of the gearbox, which had run 312 h. By current measurement the reduction was 20-27 %; the report puts the economic effect at 20 % of the power consumed.
Conclusion of the report
The results relate to the main drive gearbox of the TsPS shop conveyor at JSC Gomelsteklo and to 312 h of running after treatment; on other equipment and under other duties the figures may differ. The values for friction coefficient, oil service life and power consumption are given exactly as recorded in the conclusion of the report. The original report dated 13.04.2001 is published in full and available for download.
Current equivalent
Revitalizant gel for gearboxes →
Industrial gearboxes, final and central drives, truck and tractor gearboxes, open gear and chain drives.
How such units are treated: