VP2-10/9M air compressor — Geofizpribor Kyiv Plant JSC

← Full catalogue

INDUSTRIAL CASE STUDY|MECHANICAL ENGINEERING|COMPRESSOR EQUIPMENT

GEOFIZPRIBOR KYIV PLANT JSC · TESTIMONIAL AND REPORT OF 23.01.2002

VP2-10/9M compressor: factory dimensions without a major overhaul

Geofizpribor Kyiv Plant JSC  ·  chief engineer V. I. Seredinskiy, chief mechanic V. T. Bichevoy  ·  treatment performed by PKP Serna

Kyiv, Ukraine  ·  treatment September — October 2001  ·  control measurements after 200 hours of operation

PRODUCTXADO RVSrepair-and-restoration compounds of the XADO technology · treatment in operating mode
TEST OBJECTVP2-10/9M air compressorserial No. 1559 · stage I and II cylinders, crankshaft main journals
DOCUMENT TYPECompany testimonial and report
with signatures and seals

Key results

32,5%
output, receiver charged to 5 kgf/cm², 106 → 80 s
19,2%
oil pressure in operating mode, 2.6 → 3.1 kgf/cm²
EQUIPMENTCONDITION AT THE START OF WORKWHAT WAS MEASURED
VP2-10/9M air compressor, serial No. 1559In service since November 1987, 14 years without medium or major overhauls: output had dropped, knocking in the cylinders and the frameReceiver charging time, oil pressure, current draw, geometry of the cylinders and the crankshaft main journals

Geometry of the friction pairs: teardown before treatment and after 200 hours of operation

COMPONENTDEVIATION BEFORE TREATMENTAFTER 200 HOURS
Stage I and II cylindersovality 200-240 µmrestored to the manufacturer's dimensions
Crankshaft main journalswear up to 250 µmrestored to the manufacturer's dimensions

Instrument measurements at the first teardown and at the second one after operation. Restored surfaces: roughness Rz 0.16, hardness HRC 60-62.

Measurements in operating mode

PARAMETERBEFORE TREATMENTAFTER 200 HOURSCHANGE
Receiver charging time to 5 kgf/cm²106 s80 s−26 s, output higher by 32.5 %
Oil pressure2.6 kgf/cm²3.1 kgf/cm²+0.5 kgf/cm² (+19.2 %)
Current draw, operating mode120 A120 Ano change

Measurements in operating mode before the compressor was dismantled and after 200 hours of operation. At idle, the current draw fell by 3 A.

Conclusion of the plant and of the report

The plant's testimonial, signed by the chief engineer and the chief mechanic, states: the results of applying the XADO repair-and-restoration technology made it possible to carry out the repair in operating mode, and the repair costs proved to be 5-6× lower than those of a conventional major overhaul. The compressor came to the treatment after 14 years of service without medium or major overhauls — with reduced output and knocking in the cylinders and the frame. The second teardown after 200 hours of operation showed that the surfaces of the stage I and II cylinders and the crankshaft main journals had been restored to the manufacturer's dimensions; over the period of operation from November 2001 to February 2002 noise and vibration decreased noticeably. Conclusion of the report: the results of applying the RVS technology to restore the compressor in operating mode make it possible to recommend it for use instead of a conventional restoration repair with replacement of parts.

The results relate to a VP2-10/9M reciprocating air compressor that had run for 14 years without medium or major overhauls; on other machines and in other duty cycles the figures may differ. RVS is an obsolete XADO designation, the zero-generation compounds; the current product generation is revitalizants. The originals of the testimonial and the report, with signatures and seals, are published in full and available for download.

Current equivalent

How such units are treated: CompressorCylinder-piston groupBearings