REPORT ON TREATMENT RESULTS · 425 HOURS OF OPERATION
Booster press gearbox: tooth thickness increased, vibration and current fell
with signatures and seal
Key results
| OBJECT | CONDITION BEFORE TREATMENT | WHAT WAS MEASURED |
|---|---|---|
| Stage I and II gear drives | Stage II wheel wear over 100%, incorrect meshing of the pair | Tooth thickness over the constant chord, ShZN-18 gear tooth caliper |
| Gearbox housing, 15 control points | Vibration velocity 6.45-14.2 mm/s, vibration displacement up to 314 µm | Vibration acceleration, vibration velocity, vibration displacement |
| Drive electric motor | Drive pulley with severe radial and face runout | Current, voltage and power consumption |
Tooth thickness over the constant chord — before treatment and after 425 hours
| GEAR PAIR | BEFORE TREATMENT | AFTER 425 h | GAIN |
|---|---|---|---|
| Stage II pinion, 3 teeth | 6.6-6.7 mm | 7.0-7.1 mm | +0.3-0.5 mm |
| Stage II wheel, 5 teeth | 6.7-7.3 mm | 7.1-7.3 mm | up to +0.4 mm |
| Stage I pinion, 3 teeth | 4.0 mm | 4.3-4.35 mm | +0.3-0.35 mm |
| Stage I wheel, 5 teeth | 4.0-4.2 mm | 4.3-4.4 mm | +0.2-0.3 mm |
Measurement over the constant chord, ShZN-18: stage II m = 5.5 mm, stage I m = 4.0 mm. The metal-ceramic layer builds up along the contact patch — where the load is carried.
Drive power consumption at no load
| PARAMETER | BEFORE TREATMENT | AFTER 425 h | CHANGE |
|---|---|---|---|
| Power consumption, phase A | 8.0 kW | 7.15 kW | −10.6% |
| Power consumption, phase B | 7.8 kW | 7.07 kW | −9.4% |
| Power consumption, phase C | 8.0 kW | 7.22 kW | −9.8% |
| Supply voltage | 365 V | 366 V | mode comparable |
Measurements at 1000 rpm of the input shaft. According to the conclusion of the report, the current drawn at no load decreased by 14%.
Gearbox housing vibration, 15 control points
| QUANTITY | BEFORE TREATMENT | AFTER 425 h | TYPICAL REDUCTION |
|---|---|---|---|
| Vibration acceleration, m/s² | 12.5-85.6 | 1.88-5.28 | 77-87% |
| Vibration velocity, mm/s | 6.45-14.2 | 2.14-5.44 | 57-68% |
| Vibration displacement, µm | 147.2-314.0 | 25.7-167.3 | 5-75% |
SENDIG 911 vibrometer, 15 points on the housing; for vibration velocity a reduction was recorded at every point. For the drive pulley with severe runout the source of vibration is external.
Findings of the commission
The results refer to the two-stage gear reducer of the booster press at UKROLIIA LLC after 425 hours of operation following treatment; on other equipment and under different operating conditions the figures may differ. The original report with signatures and seal is published in full and available for download.
Current equivalent
- Revitalizant gel for gearboxesGearboxes · transmissions · gear drives
- Revitalizant gel for compressors and bearingsCompressors · bearings · spindles
How such units are treated: