INDUSTRIAL APPLICATION REPORT · 2012–2013
Fan DN-17: lower power draw and bearing vibration
with the participation of XADO LLC
Key results
| EQUIPMENT | DUTY AND OPERATING TIME | WHAT WAS MEASURED |
|---|---|---|
| Induced-draught fan DN-17 No. 1, foundry shop — drive in service | 1500 rpm, damper closed; 360 h of operation after the full treatment cycle | Motor current and power draw, apparent power (kVA) |
| Fan bearing assemblies — front and rear | Treatment cycle 19.07.2012 – 30.05.2013, final measurements 02.08.2013 | Vibration at 10 test points: bearing supports and casing base |
Electrical parameters of the drive — same duty before and after treatment
| PARAMETER | BEFORE | AFTER | CHANGE | INSTRUMENT |
|---|---|---|---|---|
| Motor current draw | 200-214 A | 192-202 A | 5.1 % | ATK2200 clamp meter |
| Motor current draw | 208-209 A | 190-192 A | 8.4 % | SMZ/KMB Systems |
| Power draw | 110-118 kW | 106-114 kW | 4.7 % | ATK2200 clamp meter |
| Apparent power (kVA) | 45.0-46.7 | 41.7-43.0 | 7.6 % | SMZ/KMB Systems |
Two independent measurement channels — an ATK2200 clamp meter and an SMZ/KMB Systems panel meter — took readings under the same duty: 1500 rpm, damper closed.
Vibration of the bearing supports and casing base — 10 test points
| MEASUREMENT POINT | VIBRATION VELOCITY, MM/S | VIBRATION ACCELERATION, M/S² | VIBRATION DISPLACEMENT, µM |
|---|---|---|---|
| Front bearing, vertical | 8.67 → 4.43 | 129 → 112 | 92.8 → 68.6 |
| Front bearing, horizontal | 6.75 → 2.94 | 155.3 → 117 | 69.8 → 45.7 |
| Front bearing, axial | 5.43 → 3.42 | 128.3 → 74.8 | 87.1 → 56.0 |
| Rear bearing, vertical | 5.92 → 2.9 | 96.1 → 84.7 | 40.0 → 15.9 |
| Rear bearing, horizontal | 5.7 → 3.09 | 101.7 → 96.2 | 63.9 → 40.9 |
| Rear bearing, axial | 5.77 → 3.2 | 99.6 → 80.5 | 85.2 → 44.6 |
| Casing base, front — horizontal | 5.57 → 2.08 | 184.0 → 55.2 | 42.8 → 31.9 |
| Casing base, front — axial | 4.08 → 1.88 | 102.3 → 66.0 | 53.5 → 16.8 |
| Casing base, rear — horizontal | 4.1 → 1.99 | 123.3 → 60.0 | 44.9 → 34.4 |
| Casing base, rear — axial | 4.89 → 1.95 | 95.2 → 82.3 | 49.9 → 24.6 |
SENDIG 911 vibrometer, measurement with the damper closed. A reduction was recorded at all ten points and for all three vibration quantities.
Commission conclusions
The results apply to induced-draught fan DN-17 No. 1 of the foundry shop of PJSC KhMZ Svet Shakhtera and to the measurement duty with the damper closed, 1500 rpm; on other equipment and under other duties the figures may differ. The original report with signatures and stamps is published in full and available for download. The treatment was performed by XADO LLC specialists, who signed the report together with the plant commission.
Current equivalent
Revitalizant gel for compressors and bearings →
Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.
How such units are treated: