PLANT REFERENCE AND TECHNICAL REPORT · 2013–2015
PLATINO 2040: turbine bearing overheating eliminated without part replacement
and KhGAPP technical reportsignatures of authorised officers, company seal
Key result
| OBJECT AND DOCUMENT | HOURS AT START | WHAT WAS RECORDED |
|---|---|---|
| PLATINO 2040 machine, blanking and stamping shop — Chief Mechanical Engineer's reference, 13.02.2013 | over 5000 h, three years in service | 23 days of normal operation after the treatment of 21.01.2013, overheating emergency stops did not recur |
| Same machine — technical report, approved by the Chief Engineer, 23.01.2015 | same, treatment 21.01.2013 | about 23 months of operation (January 2013 — December 2014), bearings never replaced, one preventive inspection with grease top-up |
Turbine bearing units: before and after treatment
| PARAMETER | BEFORE TREATMENT (December 2012 — January 2013) | AFTER TREATMENT (2013–2015) |
|---|---|---|
| Bearing unit temperature | On reaching critical values the machine's automatic emergency shutdown was triggered | Does not exceed the values permitted by the operating manual; emergency stops ceased |
| Reaching operating modes | The unit was never switched from the 14 000 rpm test mode to the operating mode | The machine runs in normal mode, turbine operating speed up to 40 000 rpm |
| Bearing condition | Extraneous noise; one bearing worn more than the others — found during disassembly on 21.01.2013 | Bearings not replaced throughout the period; over two years — one preventive inspection with a top-up of the same grease |
| Cost per unit | Set of new SR sleeves with bearings — about 93 000 UAH (2013), over 90 000 UAH (2015) | Flush and XADO "Protective 60K" grease — under 300 UAH in 2013, under 500 UAH including the top-up |
Temperature was monitored by the machine's built-in system with emergency shutdown on overheating; bearing noise and wear were assessed during unit disassembly.
Timeline: what preceded the treatment
| STAGE | WHAT WAS DONE | RESULT |
|---|---|---|
| About 4000 h of service | 10-15 g of the standard grease added to each bearing unit | Extraneous noise disappeared, later intense heating of the units developed |
| December 2012 — January 2013 | Standard grease replaced with high-speed Shell GADUS S5V42P, selected on the recommendation of its manufacturer | Heating did not stop; on severe heating the machine's emergency shutdown system was triggered |
| 21.01.2013 | Units disassembled, old grease removed, working cavities flushed, 25-30 g of XADO "Protective 60K" grease with revitalizant packed into each unit | After removing excess grease and 18-25 h of running-in, the temperature fell smoothly and stabilised — the machine was switched to the operating mode |
The unit, the fault and the maintenance personnel were the same in all three episodes — only the product changed.
Conclusions of the plant
The results relate to the generator turbine bearing units of the PRIMA POWER PLATINO 2040 laser cutting machine and to its operating conditions at KhGAPP; on other equipment and under other duty cycles the figures may differ. The originals of the reference letter of 13.02.2013 and of the technical report of 23.01.2015 are published in full and available for download.