Pump unit K-80-60-160 — DKS MZU "Smena"

← Full catalogue

FIELD CASE STUDY|PUMPING EQUIPMENT|ELECTRIC DRIVE · POWER CONSUMPTION

REPORT ON THE RESULTS OF TREATMENT UNDER CONTRACT No. 1

Pump K-80-60-160: less electricity for the same work

DKS MZU "Smena" — client  ·  contractor: ChPKP "Rigonda", director A. B. Boyko  ·  report signed on the client's side by the chief physician and the engineer

Ukraine  ·  contract No. 1 of 05.02.2003 · treatment carried out in March 2003 · control measurement after 430 hours of operation

PRODUCTXADO technologysingle-stage treatment, four assemblies of the unit, without taking the pump out of service for repair
TEST OBJECTPump unit K-80-60-160electric motor AK11212U1 · 7.5 kW · 3000 rpm · cos φ 0.86
DOCUMENT TYPEReport under contract No. 1,
signed by client and contractor

Key result

16.7-29.7%
current on all three phases under load, 10.2-12.8 → 8.5-9.0 A
UNITSPECIFICATIONWHAT WAS MEASURED
Pump K-80-60-160Centrifugal, overhung type; 4 assemblies of the unit treatedCurrent on all three phases under load
Electric motor AK11212U17.5 kW · 3000 rpm · cos φ 0.86Current on all three phases at no load

Current under load — the unit's operating mode

PHASEBEFORE TREATMENTAFTER TREATMENTCHANGE
Phase A12.8 A9.0 A29.7 %
Phase B11.6 A9.0 A22.4 %
Phase C10.2 A8.5 A16.7 %

The report records a drop in the unit's current load of 2.7 A after 430 hours of operation.

No-load current — the motor's own losses

PHASEBEFORE TREATMENTAFTER TREATMENTCHANGE
Phase A12.8 A7.8 A39.1 %
Phase B11.4 A7.7 A32.5 %
Phase C9.8 A7.0 A28.6 %

Before the treatment the no-load current was practically the same as the current under load: friction inside the unit consumed almost as much as the pumping itself.

Conclusion of the report

The contractor, ChPKP "Rigonda", stated in the report under contract No. 1: "The use of XADO technology reduces mechanical losses in the electric motor and in the unit as a whole, which leads to lower electricity consumption". The measurements confirm this at all six points — the current fell on each of the three phases both in the operating mode and at no load. The initial condition of the unit is evident from the figures themselves: under load it drew almost as much current as without it, meaning friction was eating up a considerable share of the power. After the treatment the current under load came down to 8.5-9.0 A, and this value held after 430 hours of operation — the effect is not a one-off reading taken right after the product was added. The saving over six months of round-the-clock operation was estimated by the contractor's formula at 6686 kWh.

The results refer to the pump unit K-80-60-160 with an AK11212U1 electric motor rated at 7.5 kW; on other units and duty modes the figures may differ. The electricity saving was calculated by formula by the contractor performing the treatment, ChPKP "Rigonda", and was not verified by measurement. The original report is published in full and available for download.