K-80-60-160 pump and P-1 supply fan — GAO Chernomorneftegaz

← Full catalogue

INDUSTRIAL CASE STUDY|OIL & GAS · ENERGY SAVING|PUMPS · FANS · BEARINGS

REPORTS ON THE APPLICATION OF XADO TECHNOLOGY · 2003

K-80-60-160 pump, fan and gearboxes: less friction loss and less electricity used

GAO Chernomorneftegaz, UPKhG underground gas storage and DKS MZU “Smena”  ·  contractor: ChPKP “Rigonda”  ·  approved by: A. I. Dantsev, Director of the Production Engineering Support Directorate

Crimea, Ukraine  ·  contract No. 2602/1328  ·  contract No. 1 of 05.02.2003  ·  treatment 26.02.2003 — March 2003, final report 05.09.2003

PRODUCTMixture of XADO gel and XADO greaseon worn bearings additionally — XADO “Repair” grease; single treatment
TREATED UNITSBearing assemblies of pumps, a fan and gearboxesK-80-60-160 pump · P-1 fan · boiler house pump group · washing machine gearboxes
DOCUMENT TYPEReports on the application
of XADO technology
customer and contractor signatures, stamps, approval endorsement

Key results

16,7-29,7%
current of the K-80-60-160 pump under load, 10.2-12.8 → 8.5-9.0 A
10-10,7%
current of the P-1 fan under load, 14-15 → 12.5-13.5 A
EQUIPMENTDRIVE AND ASSEMBLIESOPERATING TIME BEFORE MEASUREMENTWHAT WAS MEASURED
P-1 supply fan of the UPKhG process pump station, inventory No. 234AM160S6: 11.0 kW, 975 rpm; 4 bearing assemblies170 hPhase currents under load, bearing temperature
K-80-60-160 pump, boiler house of DKS “Smena”AK11212U1: 7.5 kW, 3000 rpm; 4 assemblies430 hPhase currents under load and at no load
Boiler house pump group: 3 continuously running unitsBearings of the motors and the pumps430 h, re-check after 6 monthsPhase currents, temperature, noise
Washing machines of the laundry department, 25 kgGearboxes, 6 h of operation per day1100 h (6 months)Phase currents

K-80-60-160 pump with AK11212U1 motor — phase currents

MODE AND MEASUREMENTPHASE APHASE BPHASE C
Under load, before treatment12.8 A11.6 A10.2 A
Under load, after 430 h of operation9.0 A9.0 A8.5 A
No load, before treatment12.8 A11.4 A9.8 A
No load, after 430 h of operation7.8 A7.7 A7.0 A
Under load, re-check after 6 months10.3 A10.2 A10.0 A

Single-stage treatment, March 2003. The current stayed below the initial level even after six months of unit operation.

P-1 supply fan with 4AM160S6 motor — phase currents

MODE AND MEASUREMENTPHASE APHASE BPHASE C
Under load, before treatment15 A15 A14 A
Under load, after 170 h of operation13.5 A13.5 A12.5 A
Motor with worn bearings, before treatment15.2 A15.5 A14.5 A
Same motor after treatment with “Repair” grease, 220 h15.2 A15.0 A13.8 A

The first current drop was recorded after 100 h of operation. With the fan running around the clock, the report estimates the saving at 582 kWh per month.

Boiler house pump group and laundry department gearboxes, DKS “Smena”

UNITWHAT WAS MEASUREDRESULT
Boiler house pump group, 3 continuously running unitsPhase currents under load, 430 hDrop of 2.7 A on average across the three phases
Same group, re-check after 6 monthsPhase currents under loadDrop of 1.4 A against the initial values still holds
Washing machine gearboxes, 25 kgPhase currents, 1100 h of operationDrop of 0.9 A
Pump group, 3 units, six months of operationElectricity saving10 400 kWh as calculated by the contractor

The saving was calculated in the report from the current reduction that actually held with the units running around the clock.

Report conclusions

The reports, approved by GAO Chernomorneftegaz and signed by both parties, state: “The application of XADO technology reduces mechanical losses in the electric motor and in the unit as a whole, which leads to lower electricity consumption.” As the experiment showed, the main friction losses occur in the bearing assemblies on the impeller shaft of the P-1 supply fan, and “reducing them is a real contribution to the Comprehensive Energy Saving Programme in Crimea.” A separate episode is the electric motor whose inspection revealed considerable bearing wear: the unit was returned to service on the spot. “The restorative repair of the electric motor bearings, carried out using XADO technology, demonstrates the possibilities of repair without disassembly. A repair that requires no purchase of expensive spare parts, no labour costs and, finally, no removal of the equipment from service.”

The results refer to the K-80-60-160 pump and the P-1 supply fan with AK11212U1 and 4AM160S6 motors, to the boiler house pump group and to the washing machine gearboxes under the operating conditions of GAO Chernomorneftegaz and DKS MZU “Smena”, 2003; on other equipment and in other duty cycles the figures may differ. The treatment and the saving calculations were performed by the contractor, ChPKP “Rigonda”. The original reports with signatures and stamps are published in full and available for download.

Current equivalent

How such units are treated: BearingsElectric motorPump