REPORT AND PROTOCOLS No. 1 AND No. 2 UNDER THE CONTRACT OF 05.02.2006
KT-4SU tram: electricity consumption fell two months in a row
signed and stamped by both parties
Key results
| OBJECT AND PERIOD | OPERATING TIME | WHAT WAS MEASURED |
|---|---|---|
| KT-4SU tram, inv. No. 36 — baseline, 1–11.03.2006 | 155.69 h on the line, 2017 km | Electricity consumption per shift |
| Same car — May 2006, after treatment | 380.74 h over 24 days, 4670 km | Electricity consumption per day |
| Same car — June 2006 | 5525 km for the month | Electricity consumption by meter for the month |
Electricity consumption per 1 km of run
| PARAMETER | BEFORE TREATMENT · MARCH | MAY 2006 | JUNE 2006 |
|---|---|---|---|
| Run for the period | 2017 km | 4670 km | 5525 km |
| Electricity consumption | 4720 kWh | 9987 kWh | 10 140 kWh |
| Specific consumption per 1 km | 2.34 kWh | 2.138 kWh | 1.835 kWh |
| Change vs. March baseline | — | −8.6 % | −21.6 % |
Consumption was read from the car's standard meter; the change vs. the March baseline follows the conclusions of protocols No. 1 and No. 2.
Electricity consumption per hour of operation on the line
| PARAMETER | BEFORE TREATMENT · MARCH | MAY 2006 |
|---|---|---|
| Time in service on the line | 155.69 h | 380.74 h |
| Electricity consumption | 4720 kWh | 9987 kWh |
| Specific consumption per 1 hour of operation | 30.32 kWh | 26.23 kWh |
| Change vs. March baseline | — | −13.5 % |
| Saving for the month at the actual operating time | — | 1557 kWh |
The saving is the difference between the actual May consumption and what the car would have drawn at the pre-treatment rate over the same operating time.
Conclusions of protocols No. 1 and No. 2
The results relate to KT-4SU tram car inv. No. 36 of the Municipal Enterprise “I. A. Pyatetsky Tram Authority” on a city route in Yevpatoria; under other operating conditions the figures may differ. The saving was calculated by PPCE “Rigonda”, which carried out the treatment. The originals of the report and of protocols No. 1 and No. 2, with signatures and stamps, are published in full and available for download.
Current equivalent