Exhauster D5B and fan VGD 5B — TETs-3 CJSC, Kharkiv

← Full catalogue

CASE SERIES|POWER GENERATION|BEARINGS · DRAUGHT MACHINES

TWO ACTS OF THE BOILER-TURBINE SHOP · TREATMENT SEPTEMBER 2005 – JANUARY 2006

series of 2 acts

Exhauster D5B and fan VGD 5B: bearing vibration and current down without dismantling

TETs-3 CJSC, boiler-turbine shop  ·  acts approved by technical director E. V. Rudinskiy, signed by the head of the boiler-turbine shop, the senior foreman for boiler equipment and the foreman of the electrical shop

Kharkiv, Ukraine  ·  treatment 23.09.2005 – 16.01.2006  ·  acts dated 22.02.2006

PRODUCTXADO revitalizant compoundsbearing assemblies treated by XADO technology — with no dismantling and no machine downtime for repair
OBJECTS OF THE SERIESSmoke exhauster D5B and hot-blast fan VGD 5Bbearings of the 320 and 200 kW drive motors, main and tail supports of the machine shafts
DOCUMENT TYPETwo acts of the TETs-3 CJSC boiler-turbine shop
with signatures and seal

What repeated on both machines

8.6-12.5%
motor current, 20 → 17.5 A and 155-160 → 141.6-144 A
7-46%
vibration velocity of bearing supports, 1.01-7.66 → 0.78-2.73 mm/s
UNITDRIVEOPERATING TIME AFTER TREATMENTWHAT WAS MEASURED
Smoke exhauster D5B, boiler-turbine shop320 kW, 710 rpm585 hVibration at 16 points, motor current, power consumption
Hot-blast fan VGD 5B, boiler-turbine shop200 kW, 985 rpm548 hVibration at 16 points, motor current across three phases

Power consumption of the drives

UNITPARAMETERBEFOREAFTERCHANGE
Exhauster D5BMotor current, A20.017.5−12.5 %
Exhauster D5BPower consumption, kW234.5206.7−11.8 %
Fan VGD 5BMotor current, phase A, A155.0141.6−8.6 %
Fan VGD 5BMotor current, phase B, A160.0143.2−10.5 %
Fan VGD 5BMotor current, phase C, A160.0144.0−10.0 %

The exhauster power was read from the electricity metering device; the fan current with clamp meters across three phases. For the fan the act states a reduction of power consumption by 9.3 %.

Vibration velocity of the bearing supports, both machines

MEASUREMENT POINTEXHAUSTER D5B, mm/sFAN VGD 5B, mm/s
Motor rear support, vertical2.41 → 0.9921.97 → 1.04
Motor rear support, horizontal2.44 → 1.792.72 → 1.67
Motor rear support, axial3.39 → 1.972.85 → 2.26
Motor front support, vertical5.78 → 1.112.09 → 2.26
Motor front support, horizontal7.66 → 2.652.24 → 1.68
Motor front support, axial3.56 → 1.882.69 → 2.51
Main shaft bearing, vertical2.7 → 2.061.01 → 0.78
Main shaft bearing, horizontal3.98 → 2.731.50 → 1.32
Main shaft bearing, axial3.45 → 2.312.23 → 1.56
Tail shaft bearing, vertical1.58 → 0.851.99 → 1.43
Tail shaft bearing, horizontal1.44 → 1.351.91 → 1.03
Tail shaft bearing, axial2.15 → 1.683.80 → 1.89

Vibrometer “SENDIG 911”, 16 control points on each machine; the table shows the bearing supports. The range in the case header is taken from here.

Supports with the highest vibration before treatment

UNITPOINT AND VALUEBEFOREAFTER
Exhauster D5BMotor front support, vibration displacement (horizontal)209.0 µm68.3 µm
Exhauster D5BMotor front support, vibration displacement (vertical)163.0 µm36.6 µm
Exhauster D5BMain shaft bearing, vibration acceleration (horizontal)28.5 m/s²18.4 m/s²
Fan VGD 5BMotor front support, vibration acceleration (axial)29.8 m/s²11.9 m/s²
Fan VGD 5BMotor rear support, vibration acceleration (vertical)14.1 m/s²4.94 m/s²
Fan VGD 5BTail shaft bearing, vibration displacement (axial)35.6 µm16.3 µm

The same instruments and the same points as in the vibration velocity table: shown are the supports that were loaded the most before treatment.

Conclusions of the acts

The commission of TETs-3 CJSC recorded in both acts. For the D5B exhauster, after the full treatment cycle and 585 hours of operation: “the power consumed by the electric motor decreased by 11.8%; the consumed current decreased by 12.5%; the vibration parameters of all bearing assemblies during exhauster operation decreased by 27-55%. At individual control points of the bearing assemblies the vibration level dropped 3-5×”. For the VGD 5B hot-blast fan, after 548 hours of operation: “the power consumed by the electric motor decreased by 9.3%; the vibration parameters of the bearing assemblies during fan operation in unloaded mode decreased by 11-46%”. Before treatment the radial clearances of the bearings reached 0.28 mm, and the vibration displacement of the supports reached 209 µm: both machines came to this result without opening the assemblies and without being taken out for repair.

The results relate to the bearing assemblies of the draught machines of the boiler-turbine shop — the D5B smoke exhauster with a 320 kW drive and the VGD 5B hot-blast fan with a 200 kW drive; on other units and in other modes the figures may differ. The originals of both acts with the signatures and seal of TETs-3 CJSC are published in full and available for download.

Current equivalent