FIELD CASE STUDY|COMPRESSED AIR|PISTON COMPRESSORS

TWO TEST REPORTS · 20.01 — 30.03.2004

series of 2 acts

FIAC and LB-30 compressors: output rose on both under working load

UNIPAK LLC, Ukraine  ·  reports approved by chief engineer A. D. Gorelov; treatment performed by engineers of XADO LLC together with the plant’s chief process engineer

Kharkiv district, Kharkiv region, Ukraine  ·  treatment 20.01.2004 · reports dated 30.03.2004

PRODUCTXADO technologytreatment of the cylinder-piston group without disassembling the compressors
TEST OBJECTSTwo piston compressors
with electric drive
FIAC AB 500-1250, inv. No. 8 · LB-30 SDB-4/100, inv. No. 3/58
DOCUMENT TYPETwo UNIPAK LLC reports
signed and stamped

What was repeated on both compressors

9-25.5%
output at working load; receiver fill 256 → 204 s and 100 → 91 s
COMPRESSORHOURS BETWEEN MEASUREMENTSWHAT WAS MEASUREDREPORT DATE
FIAC AB 500-1250, inv. No. 8560 houtput (receiver fill time), current and power by phase, vibration30.03.2004
LB-30 SDB-4/100, inv. No. 3/58410 houtput (receiver fill time), current and power by phase, vibration30.03.2004

Output: fill time of the standard receiver

COMPRESSORPRESSURE BUILD-UPTIME BEFORETIME AFTEROUTPUT GAIN
FIAC AB 500-1250, inv. No. 80 → 10 kgf/cm²7 min 55 s7 min 22 s+7.5 %
FIAC AB 500-1250, inv. No. 86 → 10 kgf/cm², working load4 min 16 s3 min 24 s+25.5 %
LB-30 SDB-4/100, inv. No. 3/580 → 10 kgf/cm²210 s208 s+1 %
LB-30 SDB-4/100, inv. No. 3/586 → 10 kgf/cm², working load100 s91 s+9 %

Both reports define the working load as the pressure build-up from 6 to 10 kgf/cm². The output gain is quoted from the conclusions of the reports.

Conclusions of the UNIPAK LLC reports

The commission of UNIPAK LLC signed two reports — one on the FIAC AB 500-1250 compressor and one on the LB-30 SDB-4/100 compressor. 1. On the FIAC AB 500-1250 after 560 hours of operation: "The output of the compressor during build-up from 0 to 10 atm increased by 7.5%, and during pressure build-up from 6 to 10 atm (which corresponds to the working load) increased by 25.5%". 2. On the LB-30 SDB-4/100: "Considering that this compressor is practically new and has little wear, no significant increase in output under working load was noted" — the gain amounted to 1% and 9%. 3. Both reports name the same cause: "the clearances in the cylinder-piston group decreased significantly and the load on the pistons increased". The compressors were not disassembled.

The results refer to the electrically driven piston compressors FIAC AB 500-1250 and LB-30 SDB-4/100 under the production conditions of UNIPAK LLC; on other units and duty cycles the figures may differ. The originals of both reports, signed and stamped, are published in full and available for download.

Current equivalent