← All methods

Piston compressors

The procedure describes restorative repair and wear protection of piston compressors without shutting down for repair and without disassembly. The treatment is carried out by adding XADO revitalizant gel in stages to the standard crankcase oil and, if a lubricator is fitted, additionally to the lubricator oil.

Procedure for treating piston compressors with XADO revitalizant gel

What is treated

When treatment is not performed

Preparation

What is measured before and after

ParameterInstrumentHow and when
Compressor output — the time in which the piston compressor fills a separate closed receiver to the operating or a fixed pressurestopwatchBefore the start of the treatment and after completion of the full cycle (items 1.4, 1.4.1).
Vibration level at fixed points in the vertical, horizontal and axial directions (vibration acceleration, vibration velocity, vibration displacement)vibrometersBefore the start of the treatment and after completion of the full cycle (item 1.4.2).
Noise level at fixed pointssound level meterMeasurements are taken at a fixed distance from the reference points with no extraneous noise sources present (item 1.4.3).
Power consumption (or current consumption) of the electric motor with the compressor unloaded and at a fixed loadelectricity meters, current clamps, wattmeter or multimeterBefore the start of the treatment and after completion of the full cycle (item 1.4.4).
Oil pressure at a fixed operating temperaturestandard or test pressure gaugeBefore the start of the treatment and after completion of the full cycle (item 1.4.5).
Operating temperature mode of the compressorDetermined before the start of the treatment and after completion of the full cycle (item 1.4.6).

Dosage rates

CompoundRateHow and when
XADO revitalizant gel for compressors and bearings (industrial)1.5 ml per 1.0 l of standard oilFor one stage of treating the compressor crankcase; 3 stages in total (items 1.5, 1.5.1).
XADO revitalizant gel for compressors and bearings — solution for addition1 part of the gel being dissolved to 5 - 10 parts of oil heated to 40 - 60°CProportion for preparing the solution in a separate container using the standard oil (item 1.5.2).
XADO revitalizant gel for compressors and bearings — for the lubricator2.0 ml per 1.0 l of lubricator oilAdded to the volume of lubricator oil required to keep the compressor running for 400 hours (item 1.5.3). Example: oil consumption through the lubricator is 0.25 l/hour, over 400 hours of continuous operation — 100.0 l, calculated amount of gel: 100.0 l x 2.0 ml = 200.0 ml (item 1.5.4).
XADO revitalizant gel — in case of increased oil consumption1.5 ml per litre of oil addedDuring the first 200 hours of operation, top up the consumed oil with an additional amount of gel dissolved in it — to maintain a constant concentration of the revitalizant in the standard oil (note 2).

Treatment stages

  1. Add the first mixture to the compressor crankcase. Start the compressor and run it in normal mode without overloads.Start of the total running time count
  2. The second stage of treating the compressor crankcase is carried out in the same way as the first stage.At an interval of 8-12 hours of total compressor operation
  3. The third stage of treating the compressor crankcase is carried out in the same way as the first stage.At an interval of 8-12 hours of total compressor operation
  4. The second mixture is fed through the lubricator in the doses required for topping up (before adding each dose it is recommended to stir the oil thoroughly), as the oil in it is consumed.Over 400 hours of operation

After treatment

Points to watch

Compounds for these units

Разборы под конкретные машины

Source: Instructions for the use of XADO revitalizant gels IE-24.6-25612000-005-2008, pages 8–9.