The procedure describes the stage-by-stage introduction of "XADO revitalizant gel for compressors and bearings (industrial)" into the standard oil of screw and centrifugal compressors. The purpose of the treatment is restorative repair and wear protection without stopping or disassembling the compressor.

Procedure for treating screw and centrifugal compressors with XADO revitalizant gel

What is treated

When treatment is not performed

Preparation

What is measured before and after

ParameterInstrumentHow and when
Vibration level at fixed points in the vertical, horizontal and axial directions (vibration acceleration, vibration velocity, vibration displacement)VibrometersIt is recommended to measure the vibration level near the bearing assemblies or at specially provided monitoring points on the housing of the screw pair. Measured before the start of the treatment and after completion of the full cycle.
Power consumption (current draw) of the electric motor with the compressor unloadedClamp meter, wattmeter or multi-parameter instrument for monitoring electrical parametersMeasured before the start of the treatment and after completion of the full cycle.
Power consumption (current draw) at a fixed pressure and in compressor idle modeMeasured before the start of the treatment and after completion of the full cycle.
Oil pressure in the compressor lubrication system at a fixed operating temperatureStandard or test pressure gaugeMeasured before the start of the treatment and after completion of the full cycle.

Dosage rates

CompoundRateHow and when
XADO revitalizant gel for compressors and bearings (industrial)0.8 mL per 1 litre of standard oil for one treatment stageRate per each stage; 5 stages in total, for new compressors or those with initial wear (up to 10%) — 3 stages at the same consumption rate.
Standard oil for dissolving the gel1 part of the gel being dissolved to 5 - 10 parts of oil heated to 50-60°CThe oil is poured into a separate container, and the prepared amount of gel is dissolved in it.

Treatment stages

  1. Prepare "XADO revitalizant gel for compressors and bearings (industrial)" at the rate of 0.8 mL per 1 litre of standard oil. Pour a small amount of standard oil heated to 50-60°C into a separate container (1 part gel to 5 - 10 parts oil), dissolve the prepared amount of gel in it and mix thoroughly until completely dissolved. Introduce the resulting mixture into the oil filler neck of the screw or centrifugal compressor. The compressor is then operated in its normal mode.Start of counting the compressor's total operating time
  2. Carry out the stage in the same way as the first one.18-24 hours of total compressor operating time between stages
  3. Carry out the stage in the same way as the first one.18-24 hours of total compressor operating time between stages
  4. Carry out the stage in the same way as the first one.18-24 hours of total compressor operating time between stages
  5. Carry out the stage in the same way as the first one.18-24 hours of total compressor operating time between stages

After treatment

Points to watch

Compounds for these units

Source: Instructions for the use of XADO revitalizant gels IE-24.6-25612000-005-2008, pages 9–10.