The nut outlasted its rated service life without replacement, weekly lubricant top-ups stopped. Russia · 2005. Observation in an operating shop, without…

## Measured

- nut service life: 3–4 months on the standard grease → 5 months 26 days with no replacement, no failure occurred — **1.5×**
- grease consumption over 177 days: 12.6 kg of weekly top-ups (calculated at 0.5 kg per week) → 2 kg charged once — **6.3×**

## Conclusion

The nut outlasted its rated service life without replacement, weekly lubricant top-ups stopped
