# Pump unit K-80-60-160 — DKS MZU "Smena"

**IE B032**  
DKS MZU "Smena" · Ukraine · 2003

Current under load dropped on all three phases, idle run became lighter, power consumption fell. Pump unit K-80-60-160, DKS MZU "Smena".

## Measured

- current on all three phases under load, 10.2-12.8 → 8.5-9.0 A — **16.7-29.7 %**
- current on all three phases at no load, 9.8-12.8 → 7.0-7.8 A — **28.6-39.1 %**

## Conclusion

Current under load dropped on all three phases, idle run became lighter, power consumption fell

Page: https://industry.xado.com/case/otchet_dks_mzu_smena_nasos_k_g
PDF report: https://industry.xado.com/pdf/TIER%20B/Smena/Nasosnyy-units-K-80-60-160/IE-B032_XADO_Smena_Nasosnyy-units-K-80-60-160_EN.pdf
Original scan: https://industry.xado.com/scans/otchet_dks_mzu_smena_nasos_k_g.pdf