# KT-4SU tram car, inv. No. 36 — I. A. Pyatetsky Tram Authority

**IE B018**  
I. A. Pyatetsky Tram Authority · Ukraine · 2006

The tram began drawing less energy per kilometer and per hour of operation, the effect grew by the second month. Ukraine · 2006.

## Measured

- electricity consumption per 1 km of run, 2.34 → 2.138-1.835 kWh/km — **8.6-21.6 %**
- electricity consumption per 1 hour of operation, 30.32 → 26.23 kWh/h — **13.5 %**

## Conclusion

The tram began drawing less energy per kilometer and per hour of operation, the effect grew by the second month

Page: https://industry.xado.com/case/otchet_kp_tramvainoe_upravlenie_g_evpatoriia_g
PDF report: https://industry.xado.com/pdf/TIER%20B/EvpatoriaTram/tram-railcars-KT-4SU-36/IE-B018_XADO_EvpatoriaTram_tram-railcars-KT-4SU-36_EN.pdf
Original scan: https://industry.xado.com/scans/otchet_kp_tramvainoe_upravlenie_g_evpatoriia_g.pdf