# Bell Air AED 22A screw compressor — PT Bina Megah Indowood

**IE C001**  
PT Bina Megah Indowood · Indonesia · 2019

Drive motor current dropped on all three phases, no-load pressure increased. Bell Air AED 22A screw compressor, PT Bina Megah Indowood. Indonesia · 2019.

## Measured

- drive motor current on all three phases under load, 40.84-43.9 → 34.5-34.7 A — **15-21.4 %**
- working pressure at idle, 4.9 → 6.3 bar — **1.4 bar**

## Conclusion

Drive motor current dropped on all three phases, no-load pressure increased

Page: https://industry.xado.com/case/report_air_screw_compressor_bellair_indonesia_en
PDF report: https://industry.xado.com/pdf/TIER%20C/PT-Bina-Megah-Indowood/screw-compressors-Bell-Air-AED-22A/IE-C001_XADO_PT-Bina-Megah-Indowood_screw-compressors-Bell-Air-AED-22A_EN.pdf
Original scan: https://industry.xado.com/scans/report_air_screw_compressor_bellair_indonesia_en.pdf