EN
INDUSTRIAL CASE|POWER GENERATION|GEARBOX · METERING PUMP

IE A038PILOT TREATMENT REPORT, MARCH — APRIL 2008

PND 100/250 metering pump: vibration and current fell without opening the gearbox

Drive current draw decreased, gearbox vibration along the X and Y axes fell. 8.6 % — current drawn by the electric drive, 3.5 → 3.2 A (2008).

Khabarovsk TETs-1 heat and power plant, boiler shop  ·  shop manager A. A. Sabin · senior foreman N. O. Gonchar · XADO concern representative V. S. Boyarkin

Khabarovsk, Russia  ·  measurements 13.03.2008 and 09.04.2008 · treatment 24.03.2008

PRODUCTXADO revitalizant compound36 ml, single addition to the gearbox oil bath
TEST OBJECTGearbox of the PND 100/250 metering pumpWorm gear, oil bath, integrated electric drive · boiler unit No. 9
DOCUMENT TYPEReport of Khabarovsk TETs-1
with signatures and stamp

Key result

↓8.6%
current drawn by the electric drive,3.5 → 3.2 A
EQUIPMENTOPERATING CONDITIONSWHAT WAS MEASURED
PND 100/250 metering pumpBoiler shop, boiler unit No. 9, phosphate pumpGearbox vibration at three control points along the X, Y and Z axes
Metering pump gearboxWorm gear in an oil bath, 650 h of operation after treatmentCurrent drawn by the integrated electric drive on all three phases

Gearbox vibration level — three control points, 650 hours of operation

CONTROL POINTAXISAMPLITUDE, µmVIBRATION VELOCITY, mm/s
Gearbox flangeX22 → 191.6 → 1.1
Gearbox flangeY60 → 502.5 → 1.8
Gearbox flangeZ18 → 120.9 → 1.1
Blind cover, worm wheel sideX39 → 231.6 → 1.3
Blind cover, worm wheel sideY28 → 201.3 → 0.8
Blind cover, worm wheel sideZ20 → 201.4 → 1.4
Cover, eccentric sideX24 → 201.6 → 1.4
Cover, eccentric sideY29 → 221.5 → 1.4
Cover, eccentric sideZ12 → 120.8 → 1.1

According to the conclusions of the report, vibration along the X and Y axes decreased by 14–41 % in amplitude and by 12–38 % in vibration velocity. The Z axis runs along the axis of the worm and the worm wheel.

Current drawn by the integrated electric drive

PHASE13.03.2008, before treatment09.04.2008, 650 h of operationCHANGE
Phase 13.5 A3.2 A−0.3 A
Phase 23.5 A3.2 A−0.3 A
Phase 33.4 A3.2 A−0.2 A

The decrease was recorded on all three phases of the drive; according to the conclusions of the report, the current drawn fell by 8 %.

Conclusions of the Khabarovsk TETs-1 commission

Based on the results of repeat measurements after 650 hours of operation, the boiler shop commission recorded the following: 1. The vibration amplitude along the X and Y axes decreased by 14–41 %; the vibration velocity along the X and Y axes decreased by 12–38 %; the current drawn decreased by 8 %. 2. The increase in vibration velocity along the Z axis, which runs along the axis of the worm, may be due to the fact that the upper rolling bearing of the gearbox worm was not exposed to the XADO revitalizant compound, since it is located outside the gearbox oil bath and is lubricated with grease. 3. The results obtained during the experiment make it possible to state that treating equipment with XADO revitalizant compounds to restore friction pairs is advisable.

Current equivalent

How such units are treated: Reduction gearbox

About this result: VibrationPower consumption

Limits of this report: The results refer to the gearbox of the PND 100/250 metering pump within boiler unit No. 9 of Khabarovsk TETs-1 after 650 hours of operation following a single treatment; on other equipment and under other operating modes the figures may differ.

Request a pilot for this unit

XADO Pilot Testing Programme

Application submitted by

Pilot treatment on the enterprise's equipment

  • any oil- or grease-lubricated assemblies: gearboxes, engines, compressors, bearings and others;
  • treatment within the regular operating cycle, without halting production;
  • instrumental measurements before and after: vibration, temperature, power consumption or current;
  • procedure for the specific assembly, dose calculation and support from a XADO engineer.

After the application, a XADO engineer will agree the units and the list of measurements with you.