TECHNICAL REPORT|MEDICAL EQUIPMENT|HANDPIECE · COMPRESSOR

IE C010TECHNICAL REPORT OF 20 DECEMBER 2000

CHIRANA turbine handpiece and compressor: play gone, faster air charging

The compressor began reaching operating pressure faster, handpiece bearing play disappeared. 16.7 % — compressor output: receiver charging to 4 kgf/cm², 35 → 30 s (2000).

Vitadent dental office, sole proprietor V. I. Olovyatenko — customer  ·  treatment performed by the private firm Stimul-plus, I. A. Almakaev

Kremenchuk, Poltava region, Ukraine  ·  report signed 20.12.2000, signatures and stamps of both parties

PRODUCTXADO technologyunits treated in normal operating mode, without disassembly
TREATED EQUIPMENTCHIRANA turbine handpiece No. 9257
and CHIRANA compressor
handpiece bearings · compressor piston group
DOCUMENT TYPEBilateral report by the customer
and the contractor

Key result

↑16.7%
compressor output: receiver charging to 4 kgf/cm²,35 → 30 s
EQUIPMENTCONDITION BEFORE TREATMENTWHAT WAS MEASURED
CHIRANA turbine handpiece No. 9257Play in the bearings, bur runout during operationBearing play, bur runout during operation
CHIRANA compressor, made in CzechiaOil passed through the piston group into the receiver; charging to 4 kgf/cm² — 35 sReceiver charging time, oil ingress into the receiver

CHIRANA compressor — before and after treatment

PARAMETERBEFORE TREATMENTAFTER TREATMENT
Receiver charging time to working pressure 4 kgf/cm²35 s30 s
Oil ingress into the receiver through the piston groupOil entered the receiverSignificantly reduced

Both time measurements were taken at the same receiver working pressure — 4 kgf/cm².

CHIRANA turbine handpiece No. 9257

PARAMETERBEFORE TREATMENTAFTER TREATMENT
Play in the handpiece bearingsPresentGone
Bur runout during operationPresentStopped

The handpiece was restored without disassembling the unit and without replacing the repair group.

Cost of restoring the units

UNITSTANDARD ROUTEWITH XADO TECHNOLOGY
CHIRANA turbine handpiece No. 9257Replacement of the repair group made in Russia, Kazan — 96.00 UAH40.00 UAH
CHIRANA compressorRepair of the piston group with the equipment taken out of service80.00 UAH

December 2000 prices as calculated by the organisation that performed the treatment; labour costs and equipment downtime are not included.

Conclusion of the report

Before treatment, the bearings of CHIRANA turbine handpiece No. 9257 had play and the bur ran out during operation; the compressor let oil through the piston group into the receiver and reached the working pressure of 4 kgf/cm² in 35 s. After treatment with XADO technology the play disappeared, the runout stopped, oil ingress into the receiver decreased significantly, and the receiver reaches the same pressure in 30 s. The worn units returned to service on site: replacement of the handpiece repair group was not required. Verbatim conclusion of the report: “Repair using the 'XADO' technology is carried out in normal operating mode and requires no special equipment, premises or spare parts”.

Current equivalent

How such units are treated: CompressorBearingsCylinder-piston group

Limits of this report: The results refer to CHIRANA turbine handpiece No. 9257 and the CHIRANA compressor of the Vitadent dental office, Kremenchuk; on other equipment and under other operating conditions the figures may differ.

Request a pilot for this unit

XADO Pilot Testing Programme

Application submitted by

Pilot treatment on the enterprise's equipment

  • any oil- or grease-lubricated assemblies: gearboxes, engines, compressors, bearings and others;
  • treatment within the regular operating cycle, without halting production;
  • instrumental measurements before and after: vibration, temperature, power consumption or current;
  • procedure for the specific assembly, dose calculation and support from a XADO engineer.

After the application, a XADO engineer will agree the units and the list of measurements with you.