IE A079TECHNICAL ACT · ROPE SHOP KTs-2
Rope machine compressors: output rose without teardown or shutdown
Compressors began filling the receiver faster, lubrication system oil pressure rose. 10–30 % — compressor output, receiver fill time 2 min 10 s – 6 min 15 s → 1 min 40 s – 5 min 10 s; 1.7 kgf/cm² — oil pressure, compressor of machine No. 112 (2002).
of VSPKZ OJSC dated 02.08.2002signatures of the customer and the contractor, company stamp
Key result
| COMPRESSOR | RECEIVER VOLUME | CONTROL PRESSURE | WHAT WAS MEASURED |
|---|---|---|---|
| Machine No. 147 | 0.2 m³ | 8 at | Fill time, output |
| Machine No. 112 | 0.075 m³ | 11 at | Fill time, output, oil pressure |
| Machine No. 101 | 0.2 m³ | 11 at | Fill time, output |
| Machine No. 128 | 0.1 m³ | 7 at | Fill time, output |
| Machine No. 127 | 0.1 m³ | 8 at | Fill time, output |
Compressor output — measured by receiver fill time
| COMPRESSOR | BEFORE TREATMENT | AFTER TREATMENT | OUTPUT, PER THE ACT |
|---|---|---|---|
| Machine No. 147 | 3 min 25 s | 3 min 05 s | +10 % |
| Machine No. 112 | 2 min 10 s | 1 min 40 s | +24 % |
| Machine No. 101 | 8 min 30 s | 8 min 20 s | +1.5 % |
| Machine No. 128 | 6 min 15 s | 5 min 10 s | +17 % |
| Machine No. 127 | 3 min 35 s | 2 min 30 s | +30 % |
The percentages are quoted as given in the act. A receiver of known volume was filled to the control pressure; the before and after measurements were taken under normal operating conditions.
What the measurements showed
Current equivalent
- Revitalizant gel for compressors and bearingsCompressors · bearings · spindles
- Revitalizant gel for cylinder restorationEngine cylinders, deep wear
How such units are treated:
About this result:
Limits of this report: The results relate to the compressors of the rope machines of rope shop KTs-2 at VSPKZ OJSC and to the measurement conditions stated in the act; on other equipment the figures may differ.