Compressor АДП-720/2,5

Treatment is carried out through the crankcase only: the lubricator is not used, and no second compound is prepared.

Compressor АДП-720/2,5: treatment through the crankcase oil bath

The class standard is 1.5 ml per litre; for this machine 1.2 ml/l has been assigned. Piston compressors →

What is treated

What is measured before and after

ParameterInstrumentHow and when
Output — filling time of a separate receiverstopwatch, calibrated pressure gaugeFrom the same initial pressure to the same final pressure, with the shut-off valves in good order.
Power consumption or current at no load and under loadclamp meter, wattmeterPhase by phase. The standard pointer instruments are unsuitable — they lack the sensitivity.
Oil pressure at a fixed operating temperaturestandard calibrated pressure gauge
Vibration level at fixed points of the framevibrometerThe points are at the main bearings of the crankshaft.
Air temperature at the outlet of each stagethermometerAt the same ambient temperature.

Dosage rates

CompoundRateHow and when
Gel for compressors and bearings1.2 ml per 1 litre of standard oil per stageThe carrier oil is heated to 60 °C, in a proportion of 1 part gel to 5–10 parts oil.

Treatment stages

  1. In a separate vessel, dilute the gel in standard oil heated to 50–60 °C (1 part gel to 5–10 parts oil), stir until completely dissolved and introduce into the crankcase of the warmed-up compressor.Start of the total operating time count
  2. The second stage is the same as the first.After 8 hours of total operating time
  3. The third stage is the same as the first.After a further 8 hours of operating time

After treatment

Points to watch

Piston compressorsCompressor

Source: XADO applied methodology, lead engineer I. N. Sharaikin. Class standard — instruction IE-24.6-25612000-005-2008, methodology No. 1. Analysis: state/DRIVE_METHODS.md.