IE A065XADO TECHNOLOGY TEST REPORT · KAUSTIK JSC
Pump R-171-15 and its motor: bearing vibration dropped with no teardown or shutdown
Vibration in the pump and motor bearings fell, the bearing units stayed in service. Heat-carrier pump R-171-15, Kaustik JSC. Russia · 2002. 24-41 %.
signed and stampedvibration measurement protocols No. 21 and No. 77 of the expertise service
Key result
| UNIT | CONDITION AT START OF TESTS | WHAT WAS MEASURED |
|---|---|---|
| Heat-carrier transfer pump item R-171-15 | Vibration-level rating — “good” | Vibration velocity Vrms at points 3x, 3y, 4x, 4y |
| Drive electric motor of the pump | Vibration-level rating — “acceptable” | Vibration velocity Vrms at points 1x, 1y, 2x, 2y, 2z |
Pump R-171-15 — vibration velocity by measurement point
| MEASUREMENT POINT | BEFORE, mm/s | AFTER, mm/s | Vrms REDUCTION |
|---|---|---|---|
| 3x | 1.9273 | 1.2610 | 34.6 % |
| 3y | 2.0066 | 1.5685 | 21.8 % |
| 4x | 1.9294 | 1.2811 | 33.6 % |
| 4y | 1.9791 | 1.6299 | 17.6 % |
| Pump average | — | — | 27 % |
Measurements by the expertise service of Kaustik JSC at fixed points on the running unit: 16 Jan 2002 — before treatment, 07 Feb 2002 — after (protocols No. 21 and No. 77).
Pump drive motor — vibration velocity by measurement point
| MEASUREMENT POINT | BEFORE, mm/s | AFTER, mm/s | Vrms REDUCTION |
|---|---|---|---|
| 1x | 3.8301 | 1.9137 | 50.1 % |
| 1y | 3.6673 | 2.7202 | 26.0 % |
| 2x | 2.8807 | 1.6950 | 41.2 % |
| 2y | 2.0230 | 1.5275 | 24.5 % |
| 2z | 2.9327 | 1.8966 | 35.3 % |
| Motor average | — | — | 35.3 % |
A drop in vibration velocity was recorded at all nine measurement points — on both treated units, the pump and the electric motor.
Commission findings and decision
The results refer to heat-carrier transfer pump item R-171-15 and its drive electric motor under the conditions of shop 28 at Kaustik JSC; on other equipment and in other operating modes the figures may differ. The original signed and stamped report is published in full and available for download.
Current equivalent
- Revitalizant gel for hydraulic systemsHydraulics · pumps · hydraulic motors
- Revitalizant gel for compressors and bearingsCompressors · bearings · spindles
How such units are treated: