PRODUCTION CASE|FOOD INDUSTRY|PISTON COMPRESSOR

IE B062TECHNICAL ACT DATED 20 AUGUST 1998

Piston compressor: higher output, vibration and overheating gone

The compressor began filling the receiver faster, vibration and overheating disappeared, noise decreased. 7.3 % — compressor output, pumping to 5.8 atm: 9 min 45 s → 9 min 05 s (1998).

Khladoprom CJSC, laundry compressor  ·  approved by V. A. Baryshevsky, President of Khladoprom CJSC  ·  treatment performed by XADO LLC: E. A. Gamidov, Executive Director, S. N. Aleksandrov, Chief Engineer

Ukraine  ·  treatment and measurements 10–20.08.1998  ·  act dated 20.08.1998

PRODUCTTreatment by XADO technologyXADO compound · treatment without removing or dismantling the unit
TEST OBJECTPiston compressorpneumatic system of the Khladoprom CJSC laundry
DOCUMENT TYPETechnical act
dated 20.08.1998

Key result

↑7.3%
compressor output, pumping to 5.8 atm:9 min 45 s → 9 min 05 s
EQUIPMENTCONDITION AT START OF TESTINGWHAT WAS MEASURED
Laundry piston compressorConsiderable noise and vibration, overheating; pumping to 5.8 atm in 9 min 45 sReceiver pumping time, noise, vibration, heating

Measurements before and after treatment — laundry compressor

PARAMETERBEFORE TREATMENTAFTER TREATMENT
Receiver pumping time to 5.8 atm9 min 45 s9 min 05 s
Noise and vibrationConsiderableNormal
HeatingOverheatingNormal

Both pumping runs were measured up to the same pressure of 5.8 atm. In the conclusions of the act, the output gain and the electricity saving are stated as 9.3 %.

Conclusions of the act

The conclusions of the act dated 20 August 1998 state: “Treatment by XADO technology made it possible to reduce the compressor pumping time by 40 s., which accordingly increased its output by 9.3% (electricity saving of 9.3%). Noise dropped to a permissible level. Vibration and overheating disappeared.” Before treatment the compressor ran with considerable noise and vibration and was overheating — a unit in such condition is normally sent for repair with disassembly. Here it was neither removed nor opened up: the compound was introduced directly into the running machine, and the laundry worked as usual for ten days. According to the measurement table of the same act, receiver pumping to 5.8 atm: 9 min 45 s → 9 min 05 s, that is 7.3 % of output gain — the compressor now delivers the same amount of air in less time and on less electricity.

Current equivalent

Revitalizant gel for compressors and bearings →

Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.

How such units are treated: Compressor

About this result: Power consumptionVibrationTemperature

Limits of this report: The results apply to the laundry piston compressor of Khladoprom CJSC treated under normal operating conditions; on other units and duty modes the figures may differ. The treatment was performed and the act was certified with a stamp by XADO LLC.

Request a pilot for this unit

XADO Pilot Testing Programme

Application submitted by

Pilot treatment on the enterprise's equipment

  • any oil- or grease-lubricated assemblies: gearboxes, engines, compressors, bearings and others;
  • treatment within the regular operating cycle, without halting production;
  • instrumental measurements before and after: vibration, temperature, power consumption or current;
  • procedure for the specific assembly, dose calculation and support from a XADO engineer.

After the application, a XADO engineer will agree the units and the list of measurements with you.