IE B051WORK COMPLETION CERTIFICATE · DNEPROMETIZ JSC
PKS 1.75U compressor: more air, less current no disassembly, in normal service
The compressor began building up pressure faster, current draw decreased. 36 % — compressor output, fill time 30 → 22 s at 3.8 kgf/cm²; 16 % — current draw, 25 → 21 A (2001).
signed and stamped by both parties
Key results
| EQUIPMENT | HOW IT WAS TREATED | WHAT WAS MEASURED |
|---|---|---|
| PKS 1.75U compressor | No disassembly, in normal operating service | Fill time at 3.8 kgf/cm², current draw |
PKS 1.75U compressor — measurements before and after treatment
| PARAMETER | BEFORE | AFTER | CHANGE |
|---|---|---|---|
| Fill time at a pressure of 3.8 kgf/cm² | 30 s | 22 s | output +36 % |
| Current draw | 25 A | 21 A | −16 % |
The measurements were taken on the running compressor, before and after treatment — at one and the same pressure of 3.8 kgf/cm².
Conclusion of the certificate
Current equivalent
Revitalizant gel for compressors and bearings →
Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.
How such units are treated:
About this result:
Limits of this report: The results apply to the PKS 1.75U compressor treated in normal operating service at Dneprometiz JSC; on other machines and in other operating modes the figures may differ. The work was performed and the certificate drawn up by the contractor Azurit Ltd.