FIAC and LB-30 compressors: output rose on both under working load

Performance under load rose on both compressors, clearances in the piston group narrowed. 9–25.5 % — output at working load; receiver fill 256 → 204 s and 100 → 91 s (2004).

UNIPAK LLC, Ukraine  ·  reports approved by chief engineer A. D. Gorelov; treatment performed by engineers of XADO LLC together with the plant’s chief process engineer

Kharkiv district, Kharkiv region, Ukraine  ·  treatment 20.01.2004 · reports dated 30.03.2004

PRODUCTXADO technologytreatment of the cylinder-piston group without disassembling the compressors
TEST OBJECTSTwo piston compressors
with electric drive
FIAC AB 500-1250, inv. No. 8 · LB-30 SDB-4/100, inv. No. 3/58
DOCUMENT TYPETwo UNIPAK LLC reports
signed and stamped

What was repeated on both compressors

↑9–25.5%
output at working load; receiver fill256 → 204 s and 100 → 91 s
COMPRESSORHOURS BETWEEN MEASUREMENTSWHAT WAS MEASUREDREPORT DATE
FIAC AB 500-1250, inv. No. 8560 houtput (receiver fill time), current and power by phase, vibration30.03.2004
LB-30 SDB-4/100, inv. No. 3/58410 houtput (receiver fill time), current and power by phase, vibration30.03.2004

Output: fill time of the standard receiver

COMPRESSORPRESSURE BUILD-UPTIME BEFORETIME AFTEROUTPUT GAIN
FIAC AB 500-1250, inv. No. 80 → 10 kgf/cm²7 min 55 s7 min 22 s+7.5 %
FIAC AB 500-1250, inv. No. 86 → 10 kgf/cm², working load4 min 16 s3 min 24 s+25.5 %
LB-30 SDB-4/100, inv. No. 3/580 → 10 kgf/cm²210 s208 s+1 %
LB-30 SDB-4/100, inv. No. 3/586 → 10 kgf/cm², working load100 s91 s+9 %

Both reports define the working load as the pressure build-up from 6 to 10 kgf/cm². The output gain is quoted from the conclusions of the reports.

Conclusions of the UNIPAK LLC reports

The commission of UNIPAK LLC signed two reports — one on the FIAC AB 500-1250 compressor and one on the LB-30 SDB-4/100 compressor. 1. On the FIAC AB 500-1250 after 560 hours of operation: “The output of the compressor during build-up from 0 to 10 atm increased by 7.5%, and during pressure build-up from 6 to 10 atm (which corresponds to the working load) increased by 25.5%”. 2. On the LB-30 SDB-4/100: “Considering that this compressor is practically new and has little wear, no significant increase in output under working load was noted” — the gain amounted to 1% and 9%. 3. Both reports name the same cause: “the clearances in the cylinder-piston group decreased significantly and the load on the pistons increased”. The compressors were not disassembled.

Current equivalent

How such units are treated: CompressorCylinder-piston group

About this result: Vibration

Limits of this report: The results refer to the electrically driven piston compressors FIAC AB 500-1250 and LB-30 SDB-4/100 under the production conditions of UNIPAK LLC; on other units and duty cycles the figures may differ.

Request a pilot for this unit

XADO Pilot Testing Programme

Application submitted by

Pilot treatment on the enterprise's equipment

  • any oil- or grease-lubricated assemblies: gearboxes, engines, compressors, bearings and others;
  • treatment within the regular operating cycle, without halting production;
  • instrumental measurements before and after: vibration, temperature, power consumption or current;
  • procedure for the specific assembly, dose calculation and support from a XADO engineer.

After the application, a XADO engineer will agree the units and the list of measurements with you.