EN
PRODUCTION CASE|CHEMICAL INDUSTRY|CENTRIFUGE · BEARINGS

IE A097MEASUREMENT REPORT ON BEARINGS No. 3636

Centrifuge bearings: clearance restored, vibration and noise down

The bearing units moved out of pre-overhaul condition, clearance decreased, the machine ran quieter. 64–68 % — bearing housing vibration, 190 and 110 → 60 and 40 µm (2001).

Pervomaisk State Enterprise “KHIMPROM”, shop 107  ·  approved by chief mechanic A. A. Pevchenko · for the shop: shop manager V. I. Burlachko, mechanic A. V. Malakhov · for XADO LLC: engineers A. I. Novikov, N. I. Babanskikh

Ukraine  ·  contract No. 20 dated 28.05.2001 · measurements on 20.07.2001 and 29.08.2001

PRODUCTXADO compoundsrestorative repair of bearings under contract No. 20
TREATED OBJECTBearings No. 3636caustic soda production centrifuge, shop 107 · two units
DOCUMENT TYPEMeasurement report before and after
restorative repair
approved by the plant's chief mechanic, chief mechanic's department stamp

Key results

↓64–68%
bearing housing vibration,190 and 110 → 60 and 40 µm
OBJECTCONDITION AT START OF WORKWHAT WAS MEASURED
Bearing No. 3636, 1stHousing vibration 190 µm — unit due for repairRadial clearance, housing vibration
Bearing No. 3636, 2ndHousing vibration 110 µmRadial clearance, housing vibration
Centrifuge as a wholeOil pressure 2.8 atm, noise level 95.5Oil pressure, noise level

Bearing units No. 3636 — measured unit by unit

PARAMETERBEARING 1stBEARING 2nd
Radial clearance, before → aftersmaller by 3.3×smaller by 3×
Housing vibration, µm190 → 60 (−68 %)110 → 40 (−64 %)

Measurements taken on 20.07.2001 and 29.08.2001 for each bearing unit; the clearance reduction and the vibration drop were obtained on both.

Centrifuge mechanism as a whole

PARAMETERBEFORE TREATMENT 20.07.2001AFTER TREATMENT 29.08.2001
Oil pressure, atm2.82.95
Noise level95.588.0

Oil pressure and noise were measured on the machine as a whole, not on individual units; the noise level unit is given exactly as recorded in the report.

Report conclusion

The commission of Pervomaisk SE “KHIMPROM” and XADO LLC recorded that, under contract No. 20 dated 28 May 2001, “restorative repair of bearings No. 3636 with XADO compounds was carried out”. At the first measurement the units were running with elevated housing vibration — 190 µm on the first bearing and 110 µm on the second. Forty days later the radial clearance of both bearings had decreased threefold, housing vibration had fallen to 60 and 40 µm, the noise level of the mechanism had dropped, and oil pressure in the system had risen from 2.8 to 2.95 atm. The restored bearing geometry is the cause of everything else here: less clearance means lower impact loads, quieter and smoother running. The centrifuge of the continuous caustic soda line gained service life without bearing replacement.

Current equivalent

Revitalizant gel for compressors and bearings →

Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.

How such units are treated: Bearings

About this result: VibrationOil pressure

Limits of this report: The results refer to bearings No. 3636 of the caustic soda production centrifuge in shop 107 of Pervomaisk SE “KHIMPROM”; on other units and duty cycles the figures may differ.

Request a pilot for this unit

XADO Pilot Testing Programme

Application submitted by

Pilot treatment on the enterprise's equipment

  • any oil- or grease-lubricated assemblies: gearboxes, engines, compressors, bearings and others;
  • treatment within the regular operating cycle, without halting production;
  • instrumental measurements before and after: vibration, temperature, power consumption or current;
  • procedure for the specific assembly, dose calculation and support from a XADO engineer.

After the application, a XADO engineer will agree the units and the list of measurements with you.