EN

Centrifugal pump

It is not the flow section that is treated but the bearing assembly — through its oil bath.

Centrifugal-type pump: treatment through the oil bath of the bearing assembly

The class standard is 1.2 ml per litre; the same rate applies here, but the interval between stages is extended to 8–12 hours. Rolling bearings, oil-lubricated →

What is treated

What is measured before and after

ParameterInstrumentHow and when
Power consumption at no loadelectricity meter, wattmeter, clamp meter—
Vibration level of the bearing supportsvibrometerIn three directions, at fixed operating modes.
Operating temperature of the bearing housingsinstrument for measuring the temperature of solids—
Radial clearance in each bearing supportdial indicator with forced shaft displacement, set of feeler gauges—

Dosage rates

CompoundRateHow and when
Gel for compressors and bearings1.2 ml per 1 litre of standard oil per stage—

Treatment stages

  1. Dilute the gel in 100–200 ml of standard oil (50–60 °C) and introduce it into the oil bath of the bearing assembly.Start of the operating-time count
  2. The second stage is the same as the first.After 8–12 hours of operation
  3. The third stage is the same as the first.After a further 8–12 hours

After treatment

Points to watch

Rolling bearings, oil-lubricatedBearings

Source: XADO applied procedure, lead engineer I. N. Sharaikin. The class standard — instruction IE-24.6-25612000-005-2008, method No. 9.

XADO Pilot Testing Programme

Application submitted by

Pilot treatment on the enterprise's equipment

  • any oil- or grease-lubricated assemblies: gearboxes, engines, compressors, bearings and others;
  • treatment within the regular operating cycle, without halting production;
  • instrumental measurements before and after: vibration, temperature, power consumption or current;
  • procedure for the specific assembly, dose calculation and support from a XADO engineer.

After the application, a XADO engineer will agree the units and the list of measurements with you.