UKPD 100 compressor · AFL hydraulic unit — Chugunoleene Invest 97 AD

← Full catalogue

INDUSTRIAL CASE|METALLURGY|COMPRESSOR · HYDRAULIC POWER UNIT · ELECTRIC DRIVE

PROTOCOL No. 1007 OF 21.10.2002 · CHUGUNOLEENE INVEST 97 AD

UKPD 100 compressor and AFL hydraulic unit: lower current, faster start-up

Motor current fell on all three phases of both machines, the compressor reached working pressure sooner. Bulgaria · 2002. 25 %, 10 %, 14.1 %.

Chugunoleene Invest 97 AD, Parvomay  ·  signed by: executive director D. Tonev, head of the electromechanical department I. Dimitrov, foreman N. Dakov  ·  treatment performed by MAY OOD, manager A. Iliev

Parvomay, Bulgaria  ·  treatment 27.09–17.10.2002  ·  protocol No. 1007 of 21.10.2002

PRODUCTXADO revitalizant gel
and XADO grease
compressor — gel into the crankcase system; hydraulic unit — grease into the bearings of the drive electric motor
TEST OBJECTUKPD 100 compressor
and AFL hydraulic unit
two units at the same plant · electric drives of 18 and 13 kW
DOCUMENT TYPECommittee protocol
with signatures and stamps

Key results

25%
power consumption of the hydraulic unit, current under load 31-33 → 24 A
10%
power consumption of the compressor, phase currents 22-24 → 20-21 A
14.1%
time for the compressor to reach working pressure, 440 → 378 s
UNITDRIVEWHAT WAS MEASURED
UKPD 100 compressor, in service18 kWMotor current on all three phases; time to reach working pressure
AFL hydraulic unit, in service13 kWMotor current on all three phases — at no load and under load

UKPD 100 compressor — motor current and time to working pressure

PARAMETERBEFORE TREATMENTAFTERCHANGE
Current, phase I22 A20 A−2 A
Current, phase II22 A20 A−2 A
Current, phase III24 A21 A−3 A
Time to reach working pressure440 s378 s−62 s

Compressor drive — 18 kW. Current dropped on all three phases; the machine now reaches working pressure 62 s sooner.

AFL hydraulic unit — motor current in two operating modes

MODE AND PHASEBEFORE TREATMENTAFTERCHANGE
No load, phase I26 A18 A−8 A
No load, phase II23 A18 A−5 A
No load, phase III25 A20 A−5 A
Under load, phase I33 A24 A−9 A
Under load, phase II32 A24 A−8 A
Under load, phase III31 A24 A−7 A

Hydraulic unit drive — 13 kW, readings taken on cold oil. Current dropped on all three phases in both modes: by 22.6-27.3 % under load and by 20.0-30.8 % at no load.

Protocol conclusion

The committee of Chugunoleene Invest 97 AD — the executive director, the head of the electromechanical department and the foreman — recorded in the protocol: after treatment with XADO technology, the power consumption of the UKPD 100 compressor fell by 10 % and that of the AFL hydraulic unit by 25 %. The current of the drive motors dropped on all three phases of both machines, and the time for the compressor to reach working pressure was cut from 440 to 378 s. The economic section of the protocol, prepared by the company that carried out the treatment — MAY OOD — puts the saving at 4.15 BGN per day for the compressor and 3.12 BGN for the hydraulic unit over eight hours of continuous operation; at a treatment cost of 71.10 and 32 BGN, it pays for itself in 17 and 10 working days respectively. The treatment was performed while both units remained in service, from 27.09 to 17.10.2002.

The results relate to the UKPD 100 compressor with an 18 kW drive and the AFL hydraulic unit with a 13 kW drive at the Chugunoleene Invest 97 AD site in Parvomay; figures may differ on other units and operating modes. The economic section of the protocol was prepared by MAY OOD, which performed the treatment. The original protocol with signatures and stamps is published in full and available for download.

Current equivalent

Revitalizant gel for compressors and bearings →

Piston, screw and centrifugal compressors; rolling and sliding bearings running in an oil bath; machine-tool spindle units and slideways.

How such units are treated: CompressorBearings